Search the Dell Virtual Rack System

Flexibility to operate at any scale

Core LAN Network: 2 x S4048-ON

High-density 1U TOR switch with forty-eight 10GbE uplinks that offers ultra-low-latency and line-rate performance optimized for data centers

Close

S4048-ON

Optimize your network for virtualization with a high-density, ultra-low-latency ToR switch that features 48 x 10GbE SFP+ and 6 x 40GbE ports (or 72 x 10GbE ports in breakout mode) and up to 720Gbps performance. The S4048-ON also supports Open Network Install Environment (ONIE) for zero-touch installation of alternate network operating systems.

  • 48 dual-speed 1/10GbE (SFP+) ports and six 40GbE (QSFP+) uplinks (totaling 72 10GbE ports with breakout cables) with OS support
  • 1.44Tbps (full-duplex) non-blocking switching fabric delivers line-rate performance under full load with sub 600ns latency
  • I/O panel to PSU airflow or PSU to I/O panel airflow
  • Supports the open source ONIE for zero-touch installation of alternate network operating systems
  • Redundant, hot-swappable power supplies and fans
  • Low power consumption
  • Support for multi-tenancy like VXLAN and NVGRE in hardware
  • Can function as a gateway switch
  • User port stacking support for up to six units managed as one logical device
  • Embedded Open Automation Framework adds VM awareness automated configuration and provisioning capabilities to simplify the management of virtual network environments
Tech Specs
Feature Description
Switch I/O bandwidth 1.44Tbps
Forwarding rate 720Gbps
Packet buffer memory 12MB
FunctionalityS4048-ON

Line-rate ports

48 x 10GbE SFP+ ports or 72 10GbE ports with breakout cables

40GbE ports

6 x 40GbE QSFP+ ports

Size

1RU, 1.71 h x 17.09 w x 17.13" d (4.35 h x 43.4 w x 46 cm d)

Weight

18.52 lbs (8.4 kg)

Power supply

100 - 240 VAC 50/60 Hz

Switch I/O bandwidth

1.44 Tbps

Forwarding rate

1080 Mpps

Switching latency

sub 600ns

Packet buffer memory

12MB

CPU memory

2GB

Redundancy

Hot swappable redundant power
Hot swappable redundant fans

Safety

UL/CSA 60950-L Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition Including all National Deviations and Group Differences, EN 60825-1 Safety of Laser Products Part1: Equipment Classification Requirements and User’s Guide, EN 60825-2 Safety of Laser Products Part 2: Safety of Optical Fibre Communications Systems, FDA Regulation 21 CFR 1040.10 and 1040.11

Emissions

Australia/New Zealand: ASNZS CISPR 22: 2006,m Class A, Canada: ICES-003, Issue-4, Class A, Europe: EN 55022: 2006+A1:2007 (CISPR 22: 2006), Class A, Japan: VCCI V3/2009 Class A

Immunity

EN300 386 V1.4.1:2008 EMC for Network Equipment, EN 55024: 1988 + A1: 2001 + A2: 2003, EN 61000-3-2: Harmonic Current Emissions, EN 61000-3-3: Voltage Fluctuations and Flicker, EN61000-4-2: ESD, EN 61000-4-3: Radiated Immunity, EN 61000-4-4: EFT, EN 61000-4-5: Surge, EN 61000-4-6: Low Frequency Conducted Immunity

RoHS

All S Series components are EU RoHS compliant

Close

OOB Management Switch: 1 x S3048-ON

TOR switch with an industry hardened operating system and support for open networking, providing freedom to run third-party operating systems

Close

S3048-ON

This open networking platform is built for high performance, software-defined data centers and provides the features to run traditional workloads and the flexibility to deploy new workloads such as Hadoop, SDS and Big Data.

  • Four SFP+ 10GbE ports for maximum flexibility and investment protection
  • I/O panel to PSU airflow or PSU to I/O panel airflow
  • Redundant, hot-swappable power supplies and fans
  • Supports ONIE for zero-touch installation of alternate network operating systems
  • Open networking offers choice of OS, such as Dell Networking OS9.X for inherent stability and feature richness, or the flexibility of a third-part OS (such as Cumulus Linux)
  • VRF-lite enables sharing of networking infrastructure and provides L3 traffic isolation across tenants (including support for multicast and IPv6 routing)
  • Enhanced automation capabilities (puppet agent, REST API extensions)
  • Supports jumbo frames for high-end performance in virtualized environments and IP storage/server communication
  • Increase VM Mobility region by stretching L2 VLAN within or across two DCs with unique VLT capabilities like Routed VLT, VLT Proxy Gateway
  • User port stacking support for up to six units managed as one logical device
  • Embedded Open Automation Framework adds VM awareness automated configuration and provisioning capabilities to simplify the management of virtual network environments

 

Tech Specs
FunctionalityS3048-ON

Line-rate ports

48 x 1000Base-T

40GbE ports

4 x 10GbE

Size

1RU, 1.71 h x 17.09 w x 12.6" d (4.4 h x 43.4 w x 32 cm d)

Weight

12.8 lbs (5.84 kg)

Power supply

90 - 264 VAC 50/60 Hz

Switch I/O bandwidth

260Gbps (full-duplex)

Forwarding rate

131 Mpps

Switching latency

3.7 microsec for 1000Base-T, 1.8 microsec for SFP+

Packet buffer memory

4MB

CPU memory

2GB

Close

Management Cluster: 2 x PowerEdge R640

Scalable computing and storage in a 1U, 2-socket platform

Close

PowerEdge R640

The PowerEdge R640 is the ideal dual-socket platform for dense scale-out data center computing and storage. Benefit from the flexibilty of 2.5” or 3.5” drives, the performance of NVMe and embedded intelligence to ensure optimized application performance in a secure platform. With embedded diagnostics and SupportAssist, the R640 delivers maximum uptime in a worry-free environment.

Highlights

  • Highly optimized air flow design enables tremendous configuration flexibility and industry-leading energy efficiency
  • Out of band management architecture facilitates rapid bare metal deployment and remediation regardless of OS state
  • Embedded SupportAssist reduces troubleshooting and downtime with embedded diagnostics and automated case creation

Automate Productivity

  • Get up to 4x performance increase for common management tasks with iDRAC9’s new dual-core ARM processor (compared with iDRAC8)
  • Use the same next-generation of embedded automation to standardize BIOS and secure boot configuration, firmware updates, server asset inventory, health monitoring, and power/reset control across all PowerEdge servers
  • Proactive automated support embedded resolves issues up to 90% faster

Comprehensive Security

  • Fully signed firmware updates; embedded trust only allows authenticated code to run
  • Security lockdown that protects your server configuration and firmware (BIOS, iDRAC, & RAID) from malicious changes
  • Secure instant erase for HDDs, SSDs, NVMs
  • New, more secure unique default password
  • Redfish, new REST-based management API, is more secure and scalable than legacy IPMI.

Tech Specs
Feature Description
Form factor 1U rack server
Processor Up to two Intel® Xeon® scalable processors, up to 28 cores per processor
Memory Up to 1.5TB
FeaturePowerEdge R640 Technical Specifications

Processor

Up to two Intel® Xeon® Scalable processors, up to 28 cores per processor

Operating System

Canonical® Ubuntu® LTS
Citrix® XenServer®
Microsoft Windows Server® with Hyper-V Red Hat® Enterprise Linux
SUSE® Linux Enterprise Server VMware® ESXi

Memory

24 DDR4 DIMM slots, Supports RDIMM /LRDIMM, speeds up to 2666, 1.5TB max
Up to 12 NVDIMM, 192GB max
Supports registered ECC DDR4 DIMMs only

Drive Bays

Front drive bays: Up to 10 x 2.5” with up to 8 NVMe, SAS/SATA/SSD/NVMe, max 58TB; up to 4 x 3.5” SAS/SATA, max 40TB
Rear drive bays: Up to 2 x 2.5” SAS/SATA/SSD/NVMe, max 12TB

RAID Controllers

Internal controllers: PERC H330, H730P, H740P, HBA330, Software RAID (SWRAID) S140
Boot Optimized Storage Subsystem: HWRAID 2 x M.2 SSDs 120GB, 240GB
External PERC (RAID): H840
External HBAs (non-RAID): 12Gbps SAS HBA

Data Protection Features

TPM 1.2/2.0 optional Cryptographically signed firmware
Secure Boot
System Lockdown
Secure erase

Power

Titanium 750W, Platinum 495W, 750W, 1100W, 1600W
48VDC 1100W, 380HVDC 1100W, 240HVDC 750W
Hot plug power supplies with full redundancy option
Up to 8 hot plug fans with full redundancy

Chassis

Optional LCD or Security bezel

Management

IPMI 2.0 compliant
iDRAC9 with Lifecycle Controller (Express, Enterprise) Quick Sync 2 wireless module optional
OpenManage Enterprise
OpenManage Mobile
OpenManage Power Center

Connectivity

OpenManage Integrations: Microsoft® System Center, VMware® vCenter™, BMC Software
OpenManage Connections: Nagios & Nagios XI, Oracle Enterprise Manager, HP Operations Manager, IBM Tivoli Netcool/OMNIbus, IBM Tivoli® Network Manager, CA Network and Systems Management

Dimensions

Form factor: Rack (1U)
Chassis depth: 705.5 mm

Ports

Network daughter card options: 4 x 1GbE or 2 x 10GbE + 2 x 1GbE or 4 x 10GbE or 2 x 25GbE
Front ports: Video, 1 x USB 2.0, available USB 3.0, dedicated IDRAC, Direct USB
Rear ports: Video, serial, 2 x USB 3.0, dedicated iDRAC network port
Video card: VGA, NVIDIA NVS310 available as PCIe card Up to 3 x Gen3 slots, all x16

Close

SAN Compute Server: 2 x PowerEdge R640

Scalable computing and storage in a 1U, 2-socket platform

Close

PowerEdge R640

The PowerEdge R640 is the ideal dual-socket platform for dense scale-out data center computing and storage. Benefit from the flexibilty of 2.5” or 3.5” drives, the performance of NVMe and embedded intelligence to ensure optimized application performance in a secure platform. With embedded diagnostics and SupportAssist, the R640 delivers maximum uptime in a worry-free environment.

Highlights

  • Highly optimized air flow design enables tremendous configuration flexibility and industry-leading energy efficiency
  • Out of band management architecture facilitates rapid bare metal deployment and remediation regardless of OS state
  • Embedded SupportAssist reduces troubleshooting and downtime with embedded diagnostics and automated case creation

Automate Productivity

  • Get up to 4x performance increase for common management tasks with iDRAC9’s new dual-core ARM processor (compared with iDRAC8)
  • Use the same next-generation of embedded automation to standardize BIOS and secure boot configuration, firmware updates, server asset inventory, health monitoring, and power/reset control across all PowerEdge servers
  • Proactive automated support embedded resolves issues up to 90% faster

Comprehensive Security

  • Fully signed firmware updates; embedded trust only allows authenticated code to run
  • Security lockdown that protects your server configuration and firmware (BIOS, iDRAC, & RAID) from malicious changes
  • Secure instant erase for HDDs, SSDs, NVMs
  • New, more secure unique default password
  • Redfish, new REST-based management API, is more secure and scalable than legacy IPMI.

Tech Specs
Feature Description
Form factor 1U rack server
Processor Up to two Intel® Xeon® scalable processors, up to 28 cores per processor
Memory Up to 1.5TB
FeaturePowerEdge R640 Technical Specifications

Processor

Up to two Intel® Xeon® Scalable processors, up to 28 cores per processor

Operating System

Canonical® Ubuntu® LTS
Citrix® XenServer®
Microsoft Windows Server® with Hyper-V Red Hat® Enterprise Linux
SUSE® Linux Enterprise Server VMware® ESXi

Memory

24 DDR4 DIMM slots, Supports RDIMM /LRDIMM, speeds up to 2666, 1.5TB max
Up to 12 NVDIMM, 192GB max
Supports registered ECC DDR4 DIMMs only

Drive Bays

Front drive bays: Up to 10 x 2.5” with up to 8 NVMe, SAS/SATA/SSD/NVMe, max 58TB; up to 4 x 3.5” SAS/SATA, max 40TB
Rear drive bays: Up to 2 x 2.5” SAS/SATA/SSD/NVMe, max 12TB

RAID Controllers

Internal controllers: PERC H330, H730P, H740P, HBA330, Software RAID (SWRAID) S140
Boot Optimized Storage Subsystem: HWRAID 2 x M.2 SSDs 120GB, 240GB
External PERC (RAID): H840
External HBAs (non-RAID): 12Gbps SAS HBA

Data Protection Features

TPM 1.2/2.0 optional Cryptographically signed firmware
Secure Boot
System Lockdown
Secure erase

Power

Titanium 750W, Platinum 495W, 750W, 1100W, 1600W
48VDC 1100W, 380HVDC 1100W, 240HVDC 750W
Hot plug power supplies with full redundancy option
Up to 8 hot plug fans with full redundancy

Chassis

Optional LCD or Security bezel

Management

IPMI 2.0 compliant
iDRAC9 with Lifecycle Controller (Express, Enterprise) Quick Sync 2 wireless module optional
OpenManage Enterprise
OpenManage Mobile
OpenManage Power Center

Connectivity

OpenManage Integrations: Microsoft® System Center, VMware® vCenter™, BMC Software
OpenManage Connections: Nagios & Nagios XI, Oracle Enterprise Manager, HP Operations Manager, IBM Tivoli Netcool/OMNIbus, IBM Tivoli® Network Manager, CA Network and Systems Management

Dimensions

Form factor: Rack (1U)
Chassis depth: 705.5 mm

Ports

Network daughter card options: 4 x 1GbE or 2 x 10GbE + 2 x 1GbE or 4 x 10GbE or 2 x 25GbE
Front ports: Video, 1 x USB 2.0, available USB 3.0, dedicated IDRAC, Direct USB
Rear ports: Video, serial, 2 x USB 3.0, dedicated iDRAC network port
Video card: VGA, NVIDIA NVS310 available as PCIe card Up to 3 x Gen3 slots, all x16

Close

SAN Compute Server: FX2 with 4 x FC630

Half-width, 1U server block ideal for hosting virtualization environments

Close

FX2 with 4 x FC630

  • 4 x FC630 server nodes
  • Have a choice of management styles – rack or blade (CMC) at the server, chassis, or rack level
  • Accelerate and simplify deployment of server and storage resources with modular blocks
  • Daisy chain chassis to manage across your infrastructure
  • Avoid overprovisioning and add resources incrementally, only as required
  • Quickly and easily build scale-out computing environment
  • Implement an unprecedented level of IT infrastructure density, allowing more services using fewer resources, resulting in overall lower costs
  • Tailor infrastructure precisely, with the right, power, storage and connectivity to meet specific workload needs
  • Easily fits the infrastructure to the workload with “bite-sized” modular blocks of computing resources that are readily deployed
  • Get more granularity resulting in better resource efficiency with unprecedented smaller chassis (2U) size

Tech Specs
FeaturePowerEdge FC630 technical specification

Form factor

Quarter-width – supports up to 8 sleds per PowerEdge FX2 enclosure

Processor

Intel® Xeon® processor E5-2600 v4 product family

Processor sockets

2

Dimensions

H: 4.03 cm (1.58 in), W: 21.09 cm (8.3 in), D: 50.83 cm (20.01 in)

Memory

Up to 768GB (24 DIMM slots): 4GB/8GB/16GB/32GB/64GB DDR4 up to 2400MT/s

I/O mezzanine cards

Access to 2 x PCIe 3.0 (x8) expansion slots

RAID controllers

Internal controllers: PERC S130 (SW RAID), PERC H330, PERC H730, PERC H730P

Primary storage

Hot-plug hard drive options:
PowerEdge Express Flash NVMe PCIe SSD, SATA HDD/SSD or SAS HDD/SSD
Up to 8 x 1.8” SSD or 2 x 2.5”

Optional adapters

Optional NICs and HBAs

Power supplies

Chassis level – PowerEdge FX2 hot-plug PSU: 2000W, 1600W AC in 1+1 redundant or 2+0 non- redundant configurations

Video card

Video type Matrox® G200 (integrated with iDRAC8)

Systems management

FX uses Chassis Management Controller (CMC) to manage all resources (server nodes and shared infrastructure) in a single web console. OpenManage portfolio for FX supports local and remote management, consistent with other PowerEdge products. Server nodes each contain proven iDRAC8 with Lifecycle Controller for agent-free, automated systems management.

Supported hypervisors

Optional supported hypervisors: VMware XenServer™

Operating systems

Microsoft® Windows Server® 2008 R2
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Microsoft Windows® HPC Server 2008
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux
VMware® ESX®

Close

SAN Storage Array: 1 x SC5020 hybrid

Affordable hybrid flash performance for mixed-workload environments

Close

SC5020

SC5020 midrange hybrid storage array offers up to 45% more IOPS, 2x greater capacity and market’s lowest hybrid array $/GB

  • Data Progression — Auto-tunes your environment for maximum performance and cost savings based on real-time usage information
  • 0 – 100% Flash Architecture — Set the mix of SSDs and HDDs to match your price/performance goals, then modify that mix as your needs change
  • Deduplication and Compression — Reduce capacity costs for both SSDs and HDDs, even on auto-tiered volumes in hybrid configurations
  • Federation – Simplify multi-array environments with quick and seamless load balancing that preserves host mappings, snapshots and replication status
  • Low-cost Business Continutiy — Keep mission-critical apps running during unexpected outages and disasters with seamless volume-level auto-failover between local and remote arrays
  • ProSupport Services — Reduce deployment costs with remote installation options that ensure your project goes right the first time

Tech Specs
Feature Description
Processors Intel® Xeon® Processor E5-2630 v3, 2.4GHz, 8 cores
Controllers 2 hot-swappable per chassis (active/active)
Operating system Dell Storage Center OS (SCOS) 7.2 or greater
Max system memory 128GB per array (64GB per controller)
Max drive count 222 (30 internal, plus 192 external)
Max raw capacity 2PB per array (SSD or HDD)
Processors Intel® Xeon® Processor E5-2630 v3, 2.4GHz, 8 cores
Controllers 2 hot-swappable per chassis (active/active)
SC5020 Specifications

Chassis Overview

Chassis format

All-in-one (dual controllers, internal drive bays, networking and expansion ports)

Rack size

3U

Controllers

2 hot-swappable per chassis (active/active)

Processors

Intel® Xeon® Processor E5-2630 v3, 2.4GHz, 8 cores

Internal storage capacity

30 x 2.5” drive bays

System memory

128GB per array (64GB per controller)

Operating system

Dell Storage Center OS (SCOS) 7.2 or greater

Expansion Capacity

Supported expansion enclosures

Dell SC420: 24 x 2.5” drive bays (12Gb SAS)
Dell SC400: 12 x 3.5” drive bays (12Gb SAS)

Maximum drive count

222 (30 internal, plus 192 external), more in federated systems*

Max raw capacity

2PB per array (SSD or HDD), more in federated systems*

Max raw capacity (NAS)

2PB per array with optional FS8600
4PB in a single namespace (with FS8600 and multiple SC Series arrays)

Storage media

SAS and NL-SAS drives; different drive types, transfer rates, rotational speeds can be mixed in the same system. SSD: write-intensive and read-intensive drives HDD: 15K, 10K, 7.2K RPM

Network and Expansion I/O

Front-end-network protocols

FC, iSCSI, SAS** (supports simultaneous multiprotocol)

Max 32Gb

FC ports 8 per array (SFP+)

Max 16Gb

FC ports 8 per array (SFP+)

Max 10Gb/1Gb

iSCSI ports Up to 8 SFP+ or BaseT ports per array

Max 12Gb

SAS ports Up to 8 12Gb SAS7 ports

Management ports

2 per array (1Gb BASE-T)

Back-end expansion protocols

12Gb SAS

Max back-end expansion ports

4 per array
Up to 16 expansion enclosures per array

Functional

Array configurations

All-flash, hybrid or HDD arrays

Storage format

Native block (SAN), file (NAS) from same pool with optional FS8600

Data Optimization

Auto-tiering method

Policy-based migration based on real-time data usage, customizable 512KB-4MB page size

Auto-tiering structure

Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

Tiering customizations

User-defined profiles, option to “pin” volumes to any tier

RAID support

RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist in single array

RAID tiering

Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups

Thin provisioning

Active by default on all volumes, operates at full performance across all features

Thin snapshots

Records changes only, snapshots auto-migrate to lower-cost storage

Intelligent deduplication and compression

Selectable option per volume on SSD and/or HDD tiers in hybrid configurations
Compression-only option also available on any configuration

HDD optimization

FastTrack moves frequently accessed data to outer tracks for quicker response times

Data Mobility and Migration

Replication Synchronous/Asynchronous via FC or iSCSI

Target/source relationships may be one-to-many or many-to-one Supports all SC data services on source and target volumes Change replication types and topologies on demand Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

Volume mobility

Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

Federated multi-array systems

Live Migrate (included in base product) enables host-transparent movement of volumes among arrays Snapshots maintained/preserved during migration

Thin Import

Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

Thin Clones

Clone standalone volumes with zero duplication of data
Clones maintain independent snapshots and replication
Ideal for VDI, test/dev, other applications that require discrete instances of common data
More efficient than dedupe for database copies

Data Protection, Disaster Recovery, Security

Business continuity

Live Volume bi-directional auto-failover, auto-repair***
Continuous operations, disaster recovery, disaster avoidance
Includes third-site (tertiary) replication options with Live Volume Managed Replication***
Zero RTO/RPO with customizable site failover SLAs per volume
Does not require identical hardware at each site
VMware Metro Stretch Cluster, VMware Site Recovery Manager support

Thin snapshots

Records changes only, snapshots auto-migrate to lower-cost storage

Replay Manager

Application-consistent snapshots in Microsoft or VMware environments

Data-at-rest encryption

Self-encrypting drives (SEDs) in SSD or HDD formats
Full Disk Encryption (FCE) based on AES-256
Drives certified to FIPS 140-2 Level 2
Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3

External key manager support

Gemalto’s SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v Thales EMS 200

Management interface

Dell Storage Manager
Multi-array, multi-site and cross-platform (PS Series) management from single interface

Federation

Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays: SC9000, SC8000, SC7020, SC5020, SC4020.*

Scripting support

Microsoft PowerShell API RESTful API

Host OS support

Microsoft® Windows Server®, Oracle® Solaris, HP®-UX, Oracle Linux, IBM® AIX®, Novell® NetWare, SLES, Apple, HPTru64, VMware®, Citrix® XenServer®, RedHat®

Third-party application integration

VMware, Microsoft, IBM, OpenStack, Oracle, Symantec, Commvault, Foglight, Docker (see SC Series Management spec sheet for more details)

Coexistence with PS Series arrays

Replication in either direction
Day-to-day management from a single interface
Thin import: space-efficient, non-disruptive data migration from PS Series arrays

Certifications

VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details

Reporting/alerts

Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

Workload management

QoS, VVOLs

Physical

Rack size

3U

Height

13.33 cm (5.25 inches)

Width

44.5 cm (17.52 inches)

Depth

78.5 cm (30.9 inches)

Weight at max configuration

24.22 kg (53.4 lb)

Weight empty

15.15 kg (33.4 lb)

Power

Power/wattage

2 hot-swappable 1485W power supplies; 1485W maximum power

Heat dissipation

5,067 BTU/hr maximum

Voltage

200-240 VAC

Frequency

50/60 Hz

Amperage

1485/100 – 14A, 1485/240 – 6.2A

Environmental Operating Conditions

Operating temperature

50 - 95°F (10 - 35°C)

Non-operating temperature

-40 - 149°F (-40 - 65°C)

Operating humidity ranges (non-condensing)

10% to 80% with 29°C (84.2°F) maximum dew point

Non-operating humidity (non-condensing)

5% to 95% with 33°C (91°F) maximum dew point

Inlet type

NEMA 5-15/CS22.2, n°42

*Multiple SC Series (SC9000, SC7020, SC5020, SC4020) arrays may be deployed in federated configurations using the Live Migrate feature included with firmware version 7.1 and above. Transparent, non-disruptive volume movement among arrays is enabled, allowing the combined capacity and cache of the entire federated cluster to be seamlessly utilized for maximum performance and scalability in expanding data centers. For example, a cluster of eight SC9000 arrays can provide a total of 8,192 drives (up to 48PB raw capacity) with over 4TB of system memory.
**Front-end SAS only supported with Dell PowerEdge 13th generation servers or later.
***Requires optional Live Volume feature.
Close
Close

Software

vCenter Server

VMware vCenter Server provides a centralized platform for managing your VMware vSphere environments, allowing you to automate and deliver a virtual infrastructure with confidence.

vSAN
VMware vSAN is the industry-leading software powering Hyper-Converged Infrastructure solutions. vSAN is a core building block for the Software-Defined Data Center.

vRealize Suite
vRealize Suite is an enterprise-ready, cloud management platform that delivers the industry’s most complete solution for managing a heterogeneous, hybrid cloud.

Close

Services and Financing

Dell EMC Professional Services

  • Solutions customized for your needs: Leverage on-site integration or application implementation with Dell EMC Professional Services.
  • Support is always on for you: Enjoy unlimited access to 24×7 chat, email and phone support services with how-to assistance and disaster recovery from Dell EMC ProSupport.
  • Deployment assistance when you need it: You can trust Dell EMC to deploy the racked configuration in your data center, including network cabling, operating system, firmware and hypervisor with Dell ProDeploy.

Dell EMC Financial Services

  • Full-service leasing and financing solutions are located throughout the US, Canada and Europe.
  • Dell EMC Financial Services can finance the total technology solution.
  • Efficient electronic quoting and online contracts offer the best customer experience.

Would You Like More Information?

Click the envelope icon at any time to use our contact form to have a Dell EMC representative get in touch with you, or click Contact Me now.

Contact Me No Thanks